Sign In | Join Free | My himfr.com
Home > Electric Heating Steam Boiler >

Professional Electric Heating Steam Boiler No Pollution Low Energy Conservation

    Buy cheap Professional Electric Heating Steam Boiler No Pollution Low Energy Conservation from wholesalers
     
    Buy cheap Professional Electric Heating Steam Boiler No Pollution Low Energy Conservation from wholesalers
    • Buy cheap Professional Electric Heating Steam Boiler No Pollution Low Energy Conservation from wholesalers

    Professional Electric Heating Steam Boiler No Pollution Low Energy Conservation

    Ask Lasest Price
    Brand Name : Yinyu
    Model Number : WDR
    Certification : ISO/BV
    Price : $5,000.00-$10,000.00
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 100 Qty/ per month
    Delivery Time : 7-30 work days
    • Product Details
    • Company Profile

    Professional Electric Heating Steam Boiler No Pollution Low Energy Conservation

    No Pollution High Efficiency Fully Automatic Electric Heating Steam Boiler


    Steam boiler steam with water, is a serious impact on the

    later use, may also cause some damage to the product, in

    order to avoid this problem, we must find out the response

    measures in a timely manner. The problem of steam belt

    water may suddenly appear during the operation of the

    boiler, which not only greatly reduces the efficiency of the

    boiler, but also has a certain impact on the safety of the

    staff. Therefore, as soon as signs of steam strip water appear,

    it must be treated immediately.
    1, the relevant standards have been clearly defined, saturated

    steam boiler steam humidity is not greater than 3% is

    qualified. If there is a more serious steam belt water, it must

    be inspected or treated from all aspects, otherwise it will

    directly affect its normal use; At the same time must ensure

    that the boiler at the normal water level, high water level will

    reduce the space of steam, and then the appearance of

    steam belt water, at the same time it is necessary to check

    whether the installation of the inner part of the boiler is in

    line with the drawing requirements, in particular, the water-

    cooled wall guide pipe and the box inserted into the cylinder

    of the seal and the drum welding requirements full welding,

    sealbetween should also be welded tightly, otherwise the

    soda mixture without the underwater plate will directly short

    into the steam pipe, causing serious steam.
    2, steam boiler between the underwater plate should be

    sealed, to prevent short circuit of the soda mixture; When the

    boiler is in operation, the continuous sewage valve should be

    opened, so that the amount of sewage in the boiler

    evaporation of about 5%, in order to reduce the expansion of

    pot water and prevent the formation of foam.
    3, the boiler internal pipe installation should be down, if

    there is no problem above, can be welded under the outlet

    pipe uniform plate a 400 x 400 x 4 steel plate, which can

    reduce the steam with water. When the boiler gas volume is

    serious, should be the air package design is too small, can be

    appropriately reduced the level of liquid, to increase the

    space of steam, reduce the amount of water with the dresser.
    4, in accordance with the above-mentioned way to carry out

    detailed inspection and improvement of the boiler, I believe

    that it will have a greatly reduced chance of water problems,

    so that the steam humidity generated by the steam boiler can

    also be controlled within the permitted range, to ensure that

    the equipment can meet the user's use requirements, of

    course, it can also extend the use of the period.
    In dealing with the problem of steam boiler steam with water,

    we must first carefully check the inside of the equipment, see

    if there is any fault problem, timely solution, in order to avoid

    the next re-emergence, must do a good job of post-

    maintenance work, this is very important, no product

    equipment can be used in the absence of maintenance for a

    long time, of course, maintenance methods must be correct

    and in line with the actual use of the boiler, maintenance

    interval is fixed, Frequent maintenance of them can only have

    bad consequences.


    Parameters


    WDR1-0.7


    NO;NameUnitNumberDescription
    1Rated outputt/h1
    2Rated working powerMpa0.7
    3Rated steam pressure170
    4Heating efficiency%99
    5Output diametermmDN50
    6Design fuels/Electric
    7Safety valve diametermmDN40
    8Bulk sizemm3420×1760×1930

    WDR2-0.7


    NO;NameUnitNumberDescription
    1Rated outputt/h2
    2Rated working powerMpa0.7
    3Rated steam pressure170
    4Heating efficiency%99
    5Output diametermmDN80
    6Design fuels/Electric
    7Safety valve diametermmDN50
    8Bulk sizemm3700×1900×2100
    Our services

    Pre-sale service:
    We help customer choose the best boiler model according to

    different requirements of various industry. Before delivery we

    will provide foundation drawing, layout drawing, boiler room

    layout, etc.
    In-sale service:
    We keep 24 hours online and keep close contacts during the

    production process to ensure on time delivery with perfect

    finished product.
    After-sale service:
    1.provide full range of original spare parts.
    2.Engineers abroad installation and commissioning service is

    available.
    3.Our engineers will held a training for boiler workers to

    ensure the safe operation.
    4.Free maintenance and repair for one year and lifelong

    service.


    Boiler application areas


    Professional Electric Heating Steam Boiler No Pollution Low Energy Conservation


    Quality Professional Electric Heating Steam Boiler No Pollution Low Energy Conservation for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Taikang Yinyu Boiler Manufacturing Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)